Published 1984 | Version v1
Miscellaneous

Fuel management studies for the Pickering NGS B reactor with reduced adjuster loading

  • 1. Ontario Hydro, Toronto, ON (Canada)

Description

The adjuster rods in Pickering NGS B provide reactivity for xenon override, and allow operation for limited time when fuelling is unavailable. The adjusters also help to shape the power distribution. However, the adjuster reactivity load produces a significant burnup penalty. In Pickering, the saving in replacement energy cost from having sufficient xenon override capability to recover from a reactor trip is smaller than the additional fuelling cost caused by the adjuster burnup penalty. This paper discusses various methods of operating the Pickering NGS B reactors with a reduced adjuster loading. This study concluded that operating Pickering NGS B with only five of the original 21 adjusters in the core, in conjunction with a four-and eight-bundle shift fuelling scheme is the best option

Part of:
Proceedings of the Canadian Nuclear Society fifth annual conference

Additional details

Publishing Information

Imprint Title
Proceedings of the Canadian Nuclear Society fifth annual conference
Imprint Pagination
132 p.
Journal Page Range
p. 1-7.
Report number
INIS-mf--12832

Conference

Title
Canadian Nuclear Society 5. annual conference.
Dates
4-5 Jun 1984.
Place
Saskatoon, SK (Canada).

Optional Information