Published 2001 | Version v1
Miscellaneous

Seismic analysis of rack structure with fluid-structure interaction

  • 1. Chungnam National Univ., Taejon (Korea, Republic of)
  • 2. KINS, Taejon (Korea, Republic of)

Description

In this study, the seismic analysis of rack structure with fluid-structure interaction is performed through use of the Finite Element Method(FEM) code ANSYS. Fluid-structure interaction can specify in terms of an hydrodynamic effect which is defined as the added mass per unit length divided by the area of the cross section. Using the Floor Response Spectrum(FRS) obtained through the time-history analysis, model analysis and seismic analysis under Operating Basis Earthquake(OBE) and Safe Shutdown Earthquake(SSE) condition is carried out. The fluid-structure interaction effects on the rack structure are investigated

Part of:
Proceedings of the KSME 2001 fall annual meeting A

Additional details

Publishing Information

Publisher
KSME
Imprint Place
Seoul (Korea, Republic of)
Imprint Title
Proceedings of the KSME 2001 fall annual meeting A
Imprint Pagination
881 p.
Journal Page Range
p. 465-470

Conference

Title
KSME 2001 fall annual meeting A
Dates
1-3 Nov 2001
Place
Jeonju (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
35102646
Subject category
S42: ENGINEERING; S36: MATERIALS SCIENCE;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
EARTHQUAKES; FINITE ELEMENT METHOD; FLOORS; FLUID-STRUCTURE INTERACTIONS; HYDRODYNAMICS; SAFETY; SEISMIC DETECTION; SHUTDOWN; SPECTRAL RESPONSE
Descriptors DEC
CALCULATION METHODS; DETECTION; FLUID MECHANICS; MATHEMATICAL SOLUTIONS; MECHANICS; NUMERICAL SOLUTION; SEISMIC EVENTS

Optional Information

Notes
7 refs, 11 figs, 1 tab