Seismic analysis of rack structure with fluid-structure interaction
- 1. Chungnam National Univ., Taejon (Korea, Republic of)
- 2. KINS, Taejon (Korea, Republic of)
Description
In this study, the seismic analysis of rack structure with fluid-structure interaction is performed through use of the Finite Element Method(FEM) code ANSYS. Fluid-structure interaction can specify in terms of an hydrodynamic effect which is defined as the added mass per unit length divided by the area of the cross section. Using the Floor Response Spectrum(FRS) obtained through the time-history analysis, model analysis and seismic analysis under Operating Basis Earthquake(OBE) and Safe Shutdown Earthquake(SSE) condition is carried out. The fluid-structure interaction effects on the rack structure are investigated
Additional details
Publishing Information
- Publisher
- KSME
- Imprint Place
- Seoul (Korea, Republic of)
- Imprint Title
- Proceedings of the KSME 2001 fall annual meeting A
- Imprint Pagination
- 881 p.
- Journal Page Range
- p. 465-470
Conference
- Title
- KSME 2001 fall annual meeting A
- Dates
- 1-3 Nov 2001
- Place
- Jeonju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 35102646
- Subject category
- S42: ENGINEERING; S36: MATERIALS SCIENCE;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- EARTHQUAKES; FINITE ELEMENT METHOD; FLOORS; FLUID-STRUCTURE INTERACTIONS; HYDRODYNAMICS; SAFETY; SEISMIC DETECTION; SHUTDOWN; SPECTRAL RESPONSE
- Descriptors DEC
- CALCULATION METHODS; DETECTION; FLUID MECHANICS; MATHEMATICAL SOLUTIONS; MECHANICS; NUMERICAL SOLUTION; SEISMIC EVENTS
Optional Information
- Notes
- 7 refs, 11 figs, 1 tab