Published 1981 | Version v1
Book Open

Dosimetry in boron neutron capture therapy

  • 1. Rikkyo Univ., Yokosuka, Kanagawa (Japan). Inst. for Atomic Energy
  • 2. Teikyo Univ., Tokyo (Japan)
  • 3. Musashi Inst. of Tech., Kawasaki, Kanagawa (Japan). Atomic Research Lab.

Description

Boron neutron capture therapy is based on the irradiation of charged particles in the tumour cells. The dose in the tumour is equal to the total energy from the 10B(n,α)7 Li reaction, which is proportional to the product of the neutron fluence and the 10B concentration in the tumour. Dosimetry for medical therapy implies the monitoring of the neutron fluence and the measurement of 10B concentrations. The neutron fluence was determined by miniaturized silicon detectors covered with 6LiF. The detectors are manufactured in our laboratory and have been successfully utilized for clinical purposes. The 10B concentrations have, up to now, been measured by chemical analysis. Another measuring system is being studied for practical application. In this system the 0.48 MeV prompt gamma rays emitted from 7Li nuclei are detected by Ge(Li) gamma detectors. Errors are 3% for 30 ppm of 10B and 30% for 1 ppm of 10B when the sample volume is 0.28 cm3 and the counting time is 1000 seconds. Some clinical results of the boron neutron capture therapy are also described. (author)

Files

14728373.pdf

Files (807.8 kB)

Name Size Download all
md5:4806a85448a525fc7a6eabb748df0df5
807.8 kB Preview Download

Additional details

Publishing Information

Publisher
IAEA.
Imprint Place
Vienna
ISBN
92-0-010281-6
Imprint Title
Biomedical dosimetry: physical aspects, instrumentation, calibration
Imprint Pagination
596 p.
Series
Proceedings series.
Journal Page Range
p. 173-186.

Conference

Title
physical aspects, instrumentation, calibration.
Acronym
International symposium on biomedical dosimetry
Dates
27 - 31 Oct 1980.
Place
Paris (France).

Optional Information

Secondary number(s)
IAEA-SM--249/20.