Corrosion and indices of operating reliability of steam-water circuits of foreign NPP

Description

Corrosion failures in circuits of foreign NPPs are considered. According to American statistics there are more corrosion failures in two-circuit NPPs than in NPPs with one circuit. Steam generators mostly suffer from ''corrosion denting''. Lately pitting corrosion becomes a potentially serious problem. Steam generator vertical tubes are maiply subjected to this corrosion type. Attention is drawn to intercrystalline corrosion. The causes of corrosion are described. The problem of optimization of structural materials is discussed to reduce corrosion failures as well as other methods of decreasing corrosion failures. Organization of nondestructive testing, increased requirements to water and steam purity are of great importance

Additional details

Additional titles

Original title (Russian)
Korroziya i pokazateli nadezhnosti ehkspluatatsii parovodyanykh konturov zarubezhnykh AEhS

Publishing Information

Journal Title
Teploehnergetika
Journal Issue
no.12
Series
Teploehnergetika.
ISSN
0040-3636

Optional Information

Notes
For English translation see the journal Thermal Engineering (UK).