Magnetic susceptibility artifacts with superparamagnetic gastrointestinal contrast media

Description

This paper reports on superparamagnetic gastrointestinal contrast agents for MR imaging which have limited effectiveness because of magnetic susceptibility artifacts and image distortion. The authors hypothesize that these artifacts can be circumvented by optimizing the concentration and viscosity of the formulation. Phantom and canine studies (n = 39) were performed with a new superparamagnetic agent (WIN 39996, Sterling Drug). A 250 μg of iron per milliliter aqueous suspension was diluted from 10% - 100% wt/wt (10% increments). Viscosity varied from 1 to 600 CPS (150 CPS increments) using Xanthan gum. MR imaging was performed at 1.5 T with spin-echo (TR/TE 300/15 and 2,000/35,70 with fat saturation) and gradient-echo sequences (25-40/13/30 degrees), initially and after 1 hour of gravitational settling. All concentrations at 1 CPS caused susceptibility artifacts. For 150-600 CPS formulations, 50% - 60% wt/wt concentrations yielded good negative contrast with the same susceptibility changes as air in vitro, and no susceptibility artifacts seen in vivo, even with gradient-echo and fat-saturated sequences, up to 1 hour. Higher concentrations produced artifacts; lower concentrations provided insufficient negative contrast

Additional details

Additional titles

Subtitle (English)
Importance of optimizing formulation

Publishing Information

Publisher
Radiological Society of North America Inc.
Imprint Place
Oak Brook, IL (United States)
Imprint Title
Seventy seventh assembly and annual meeting of the Radiological Society of North America
Imprint Pagination
469 p.
Journal Page Range
p. 93.

Conference

Title
77. scientific assembly and annual meeting of the Radiological Society of North America.
Dates
1-6 Dec 1991.
Place
Chicago, IL (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
23053728
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference, Numerical Data
Descriptors DEI
CONTRAST MEDIA; DOGS; EVALUATION; EXPERIMENTAL DATA; IMAGE PROCESSING; MAGNETIC SUSCEPTIBILITY; NMR IMAGING; OPTIMIZATION; PHANTOMS; SEQUENTIAL SCANNING; SPIN ECHO; SUPERPARAMAGNETISM; VISCOSITY
Descriptors DEC
ANIMALS; COUNTING TECHNIQUES; DATA; DIAGNOSTIC TECHNIQUES; INFORMATION; MAGNETIC PROPERTIES; MAGNETISM; MAMMALS; MOCKUP; NUMERICAL DATA; PHYSICAL PROPERTIES; STRUCTURAL MODELS; VERTEBRATES

Optional Information

Secondary number(s)
CONF-911201--.