A 71-year-old patient with high-output cardiac failure was found to have an aneurysmal distal aorta with evidence of an arteriocaval fistula on ultrasound scanning. CT demonstrated an aneurysm of the distal aorta and right common iliac artery and an intraarterial digital subtraction angiogram confirmed an arteriocaval fistula. In view of the patient's cardiac failure and general condition an endovascular stent was considered. The right internal iliac artery was occluded with Tungsten coils prior to the insertion of a bifurcated stent-graft. This resulted in total occlusion of the aneurysm and obliteration of the arteriocaval fistula. To our knowledge such a case has not been previously reported
Additional details
Identifiers
Publishing Information
- Journal Title
- Cardiovascular and Interventional Radiology
- Journal Volume
- 21
- Journal Issue
- 3
- Journal Page Range
- p. 244-246
- ISSN
- 0174-1551
- CODEN
- CAIRDG
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 39093069
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AORTA; FAILURES; GRAFTS; PATIENTS; TUNGSTEN; VASCULAR DISEASES
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DISEASES; ELEMENTS; METALS; ORGANS; REFRACTORY METALS; TRANSITION ELEMENTS; TRANSPLANTS
Optional Information
- Copyright
- Copyright (c) 1996 Springer-Verlag New York Inc.