Description

The response of YAP:Ce scintillators to energetic heavy ions in the mass range A = 20-200 has been studied. The pulse height and the pulse height resolution have been explored in details for a single YAP:Ce crystal, coupled to R4141 PMT, by using 20Ne, 40Ar, 84Kr, 129Xe and 197Au beams having energies ranging from 40 A MeV to 15 A MeV. Energy degraded beams have also been employed in order to cover a large energy range. Finally, timing properties were studied in the BIGSOL spectrometer at Texas A and M by measuring the heavy fragment time-of-flight against a PPAC detector

Availability note (English)

Available online at http://stacks.iop.org/1742-6596/41/143/jpconf6_41_013.pdf or at the Web site for the Journal of Physics. Conference Series (Online) (ISSN 1742-6596) http://www.iop.org/

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
41
Journal Issue
1
Journal Page Range
p. 143-150
ISSN
1742-6596

Conference

Title
19. nuclear physics divisional conference: New trends in nuclear physics applications and technology
Acronym
European Physical Society EUROCONFERENCE
Dates
5-9 Sep 2005
Place
Pavia (Italy)