Published January 1994 | Version v1
Report Open

Large area self-powered gamma ray detector

Description

The purpose of this research was to develop a large area self-powered gamma detector (LASPGD) capable of detecting the movement of sealed radiation sources into and out of industrial radiographic units and to construct a prototype source position monitor (SPM) for these units utilizing the LASPGD. Prototype isotropic and directional LASPGDs, with solid and inert gas dielectrics, were developed and extensively tested using calibrated gamma sources (i.e., Cs-137, and Co-60). The sensitivities of the isotropic detectors, with inert gas dielectrics, were found to be approximately a factor of ten greater than those measured for the solid dielectric LASPGDs. Directionally sensitive self-powered detectors were found to exhibit a forward-to-back hemispherical sensitivity ratio of approximately 2 to 1. Industrial radiographic units containing Ir-192 sources with different activities were used to test the performance of the SPM. The SPM, which utilized a gas dielectric LASPGD, performed as designed. That is, the current generated in the LASPGD was converted to a voltage, amplified and used to control the on/off state of an incandescent lamp. The incandescent lamp, which functions as the source/out warning indicator, flashes at a rate of one flash per second when the source is in use (i.e. out of its shield)

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as TI94006055; NTIS; GPO.

Files

25044926.pdf

Files (2.7 MB)

Name Size Download all
md5:a58b3bf0d4a1759d89bdccd0fa1bd664
2.7 MB Preview Download

Additional details

Additional titles

Subtitle (English)
Phase 2, Development of a source position monitor for use on industrial radiographic units

Publishing Information

Imprint Pagination
36 p.
Report number
NUREG/CR--4833

Optional Information