Description

By exposing samples to various irradiance levels from a calibrated thermal radiation source, the ignition responses of blackened alpha-cellulose and cotton cloth with and without fire-retardant additives were compared. Samples treated with retardant compounds which showed the most promise were then isothermally pyrolyzed in air for comparisons between the pyrolysis rates. Alpha-cellulose samples containing a mixture of boric acid, borax, and ammonium di-hydrogen phosphate could not be ignited by irradiances up to 4.0 cal cm-2 s-1 (16.7 W/cm2). At higher irradiances the specimens ignited, but flaming lasted only until the flammable gases were depleted. Cotton cloth containing a polymeric retardant with the designation THPC + MM was found to be ignition-resistant to all irradiances below 7.0 cal cm-2 s-1 (29.3 W/cm2). Comparison of the pyrolysis rates of the retardant-treated alpha-cellulose and the retardant-treated cotton showed that the retardant mechanism is qualitatively the same. Similar ignition-response measurements were also made with specimens exposed to ionizing radiation. It was observed that gamma radiation results in ignition retardance of cellulose, while irradiation by neutrons does not

Availability note (English)

MF available from INIS under the Report Number.

Files

8281352.pdf

Files (197.9 kB)

Name Size Download all
md5:dab3b503c05aeda479d24b93a5d7899c
197.9 kB Preview Download

Additional details

Additional titles

Augmented title (English)
Fire retardants; effects of irradiation

Publishing Information

Imprint Pagination
7 p.
Report number
UCRL--78026

Conference

Title
American Chemical Society meeting.
Dates
29 Aug 1976.
Place
San Francisco, California, United States of America (USA).

Optional Information

Notes
Available from NTIS. $3.50.
Secondary number(s)
CONF-760826--4.