Water activation in a fusion environment

  • 1. Argonne National Lab., IL (United States)
  • 2. Rensselaer Polytechnic Inst., Troy, NY (United States)
  • 3. Japan Atomic Energy Research Inst., Ibaraki (Japan)
  • 4. V.G. Khlopin Radium Inst., St. Petersburg (Russian Federation)

Description

Water is activated in a fusion environment by the 16O(n,p)16N reaction. In this work nuclear responses in the magnets, induced by gamma rays from the activated cooling water, for the current design of the International Thermonuclear Experimental Reactor (ITER), are calculated with a detailed Monte Carlo model of the chimney region through which the cooling pipes leave the machine. It is found that, despite a significant dose, the nuclear responses induced by these gamma-rays do not pose an obvious threat to the operation of the magnets. 8 refs., 3 figs., 1 tab