Description

This report presents status of external and internal dose assessment of workers and introducing the structure of National Dose Registry System of Iran (NDRSI). As well as types of individual dosemeters in use, techniques for internal dose assessment are presented. Results obtained from the International Atomic Energy Agency intercomparison programme on measurement of personal dose equivalent Hp (10) and consistency of the measured doses with the delivered doses are shown. Also, implementation of dosimetry standards, establishment of quality management system, authorisation and approval procedure of dosimetry service providers are discussed. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncq297

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
144
Journal Issue
1-4
Journal Page Range
p. 52-55
ISSN
0144-8420

Conference

Title
European conference on individual monitoring of ionising radiation
Acronym
IM2010
Dates
8-12 Mar 2010
Place
Athens (Greece)

Optional Information

Notes
9 refs