Published October 2006 | Version v1
Journal article

Assessing the 210At impurity in the production of 211At for radiotherapy by 210Po analysis via isotope dilution alpha spectrometry

  • 1. National Institute of Standards and Technology, Radioactivity Group, 100 Bureau Drive MS8462, Gaithersburg, MD 21702 (United States)
  • 2. National Institutes of Health, Cyclotron Facilities, 10 Center Drive, Bethesda, MD (United States)
  • 3. International Atomic Energy Agency, Dosimetry and Radiation Physics Section, Wagramer Strasse 5, P.O. Box 100, A-1400 Vienna (Austria)

Description

A method for assessing the impurity 210At in cyclotron-produced 211At via isotope dilution alpha spectrometry is presented. The activity of 210At is quantified by measuring the activity of daughter nuclide 210Po. Counting sources are prepared by spontaneous deposition of Po on a silver disc. Activity of 210At (at the time of 210Po maximum activity) is found to be 83.5+/-9.0Bq, corresponding to an atom ratio (210At:211At at the time of distillation) of 0.010+/-0.007% (k=2). The method produces high-quality alpha spectra, with baseline alpha-peak resolution and chemical yields of greater than 85%

Additional details

Identifiers

DOI
10.1016/j.apradiso.2006.02.046;
PII
S0969-8043(06)00100-X;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
64
Journal Issue
10-11
Journal Page Range
p. 1365-1369
ISSN
0969-8043
CODEN
ARISEF

Conference

Title
15. international conference on radionuclide metrology and its applications
Acronym
ICRM 2005
Dates
5-9 Sep 2005
Place
Oxford (United Kingdom)

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.