Robust classification of neonatal apnoea-related desaturations

  • 1. CIBER de Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza (Spain)
  • 2. Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford (United Kingdom)

Description

Respiratory signals monitored in the neonatal intensive care units are usually ignored due to the high prevalence of noise and false alarms (FA). Apneic events are generally therefore indicated by a pulse oximeter alarm reacting to the subsequent desaturation. However, the high FA rate in the photoplethysmogram may desensitize staff, reducing the reaction speed. The main reason for the high FA rates of critical care monitors is the unimodal analysis behaviour. In this work, we propose a multimodal analysis framework to reduce the FA rate in neonatal apnoea monitoring. Information about oxygen saturation, heart rate, respiratory rate and signal quality was extracted from electrocardiogram, impedance pneumogram and photoplethysmographic signals for a total of 20 features in the 5 min interval before a desaturation event. 1616 desaturation events from 27 neonatal admissions were annotated by two independent reviewers as true (physiologically relevant) or false (noise-related). Patients were divided into two independent groups for training and validation, and a support vector machine was trained to classify the events as true or false. The best classification performance was achieved on a combination of 13 features with sensitivity, specificity and accuracy of 100% in the training set, and a sensitivity of 86%, a specificity of 91% and an accuracy of 90% in the validation set. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/0967-3334/33/9/1503

Additional details

Identifiers

Publishing Information

Journal Title
Physiological Measurement (Print)
Journal Volume
33
Journal Issue
9
Journal Page Range
p. 1503-1516
ISSN
0967-3334

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47049910
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE; S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
Descriptors DEI
ACCURACY; CLASSIFICATION; ELECTROCARDIOGRAMS; HEART; IMPEDANCE; MONITORING; NOISE; OXYGEN; QUALITY ASSURANCE; SENSITIVITY; SIGNALS; TRAINING; VALIDATION
Descriptors DEC
BODY; CARDIOVASCULAR SYSTEM; DIAGRAMS; EDUCATION; ELEMENTS; INFORMATION; NONMETALS; ORGANS; TESTING