Published March 1991 | Version v1
Report

Evaluation of passive safety injection system

Creators

Description

The passive safety injection system (PSIS) requirements from the advanced light water reactor (ALWR) plant requirements document and descriptions from the open literature on the Westinghouse AP600 pressurized water reactor (PWR) were reviewed to develop a PWR PSIS system description for this assessment. The PSIS is based on a reactor with a thermal power of 1,812 MW(t). The system description emphasizes the physical size, layout, and configuration of the pressure boundary hardware. In addition to the system description, this paper describes system operation, functions, performance requirements, and scope of transient and safety analyses

Additional details

Publishing Information

Imprint Title
PWR passive plant heat removal assessment: Joint EPRI-CRIEPI advanced LWR studies. Final report
Imprint Pagination
71 p.
Journal Page Range
p. 3.1-3.17.
Report number
EPRI-NP--7080-M