CT coronary angiography: Quantitative assessment of myocardial perfusion using test bolus data-initial experience
Creators
- 1. University College Hospital, UCLH NHS Foundation Trust, Institute of Nuclear Medicine, London (United Kingdom)
- 2. Mount Vernon Hospital, Paul Strickland Scanner Centre, Middlesex (United Kingdom)
- 3. Hospitals of the University of Nottingham, Nottingham (United Kingdom)
Description
The aim of this study is to quantify myocardial perfusion during coronary CT angiography using data from a modified timing test-bolus acquisition. Institutional review board approval and informed consent were obtained. Nineteen patients with suspected coronary artery disease underwent combined coronary CT angiography and cardiac 82Rubidium-PET perfusion. Prior to the CT angiogram a retrospectively ECG-gated dynamic test bolus was obtained following 25 mls of IV contrast medium injected at 5 ml/s. Images were acquired every 1.5 s for 30 s using 4 x 1.25-mm slices at 120 kV, 35 mAs. Regions of interest were drawn to delineate the myocardium and aorta on the resulting transaxial images. Time density curves were created and perfusion calculated using two simple approaches: maximum-slope method and peak method. In patients with normal PET myocardial perfusion, the mean (SD) resting myocardial perfusion estimated by CT using the maximum-slope method was 0.89 (±0.27) ml/min/g and 0.93 (±0.21) ml/min/g at end-systole and end-diastole, respectively, and 0.69 (±0.11) ml/min/g and 0.79 (±0.19) at end-systole and end-diastole, respectively, for the peak method. Thus quantification of myocardial perfusion from a routine coronary CT angiography test bolus is possible. CT-derived myocardial perfusion values are consistent with published values derived from other techniques. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-008-0987-9Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 18
- Journal Issue
- 10
- Journal Page Range
- p. 2155-2163
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 39106384
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- COMPUTERIZED TOMOGRAPHY; MYOCARDIUM; PERFUSED ORGANS; PERFUSED TISSUES; POSITRON COMPUTED TOMOGRAPHY; RUBIDIUM 86
- Descriptors DEC
- ANIMAL TISSUES; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; DAYS LIVING RADIOISOTOPES; DIAGNOSTIC TECHNIQUES; ELECTRON CAPTURE RADIOISOTOPES; EMISSION COMPUTED TOMOGRAPHY; HEART; INTERMEDIATE MASS NUCLEI; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MINUTES LIVING RADIOISOTOPES; MUSCLES; NUCLEI; ODD-ODD NUCLEI; ORGANS; RADIOISOTOPES; RUBIDIUM ISOTOPES; TOMOGRAPHY