The study of discharge cleaning in the JFT-2 tokamak with surface observation by AES

  • 1. Japan Atomic Energy Research Inst., Tokai, Ibaraki. Tokai Research Establishment

Description

Noticeable correlations were observed between the changes of discharge characteristics, wall conditions and typical mass peaks with discharge cleaning in the JFT-2 tokamak. Atomic composition of the vacuum wall surface observed by AES becomes constant with continuing discharge cleaning in the level except hydrogen and helium: 30-50% C, 20-30% Mo, 15-30% stainless steel elements and 10-15% O. The stable reproducible plasma with Z sub(eff)=4.5 was obtained in this wall condition. The limiter and vacuum wall materials (Mo and 304 stainless steel, respectively), carbon and oxygen were observed depositing on the wall in the thickness of about 300 A at the minimum inner radius of the vacuum chamber and 40 A nearly at the maximum after 2900 cleaning pulses. The mechanism determining the wall condition is also discussed. (auth.)

Availability note (English)

MF available from INIS under the Report Number.

Files

8314028.pdf

Files (530.7 kB)

Name Size Download all
md5:ea6ed8a3eb30d5253258f50d553c8bcd
530.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
16 p.
Report number
JAERI-M--6647