Published September 1992 | Version v1
Journal article

Laplace transform method in analysing the effect of amplifier parameter on identification of light charged particles with CsI(Tl) + PD (photodiodes) detector

  • 1. Academia Sinica, Lanzhou, GS (China). Inst. of Modern Physics

Description

Laplace transform method is applied to investigate the effect of the choice of amplifier parameter on identification of the light charged particles emitted from 12C(46.7 MeV/u) + 58Ni reaction. The significance of application of Laplace transformation method in heavy ion experimental nuclear physics is discussed as well

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
12
Journal Issue
suppl.
Series
Proceedings of 6th national coference on nuclear electronics and nuclear detection technology (A).
Journal Page Range
p. 44-47.
ISSN
0258-0934
CODEN
HDYUEC

Conference

Title
6. national conference on nuclear electronics and nuclear detection technology.
Dates
21-26 Sep 1992.
Place
Weihai (China).