The Effect of Eddy Current Bobbin Coil Dimension Changes on Signal Quality of Steam Generator
- 1. Korea Electric Power Research Institute, Daejeon (Korea, Republic of)
Description
The bobbin probe is now widely accepted as a basic and important ECT technique among various ECT techniques for steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe is also one of the essential components which consist of the whole ECT examination system, and provides us with decisive data for the evaluation of tube integrity in accordance with acceptance criteria described in specific procedures. Accordingly, the design of ECT probe is especially important to examination results because the quality of acquired ECT data is determined by the optimized probe design characteristics, such as coil geometry, electrical properties, operation frequency, and so on. In this study, the relationship between electric characteristic changes and differential coil gap variation for the optimization of the ECT probe signal was investigated
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2008 spring meeting of the KNS
- Dates
- 29-30 May 2008
- Place
- Kyeongju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 39109374
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- DESIGN; EDDY CURRENTS; OUTAGES; PROBES; SIGNALS; STEAM GENERATORS; TUBES
- Descriptors DEC
- BOILERS; CURRENTS; ELECTRIC CURRENTS; VAPOR GENERATORS
Optional Information
- Notes
- 2 refs, 4 figs