Published May 13, 1999 | Version v1
Report

Uranium oxidation rate summary for the spent nuclear fuel project; TOPICAL

Description

This report documents the results the acceptance test NHF-4108 which verifies the MICON program changes for the new automatic transfer switch ATS-2 alarms, the Closed Loop Cooling isolator status, the CB-3 position alarm, the alarms for the new emergency fan damper backup air compressor, and the generator sequencer logic

Availability note (English)

Available from OSTI as DE00782326; www.osti.gov/servlets/purl/782326-bMAKfj/native/; www.osti.gov/servlets/purl/782326-UxLxhD/webviewable/

Additional details

Publishing Information

Imprint Pagination
85 p.
Report number
HNF--4165-REV0

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
33066638
Subject category
S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
AIR; BLOWERS; NUCLEAR FUELS; OXIDATION; URANIUM
Descriptors DEC
ACTINIDES; CHEMICAL REACTIONS; ELEMENTS; ENERGY SOURCES; FLUIDS; FUELS; GASES; MATERIALS; METALS; REACTOR MATERIALS

Optional Information

Contract/Grant/Project number
AC06-96RL13200
Funding organization
US DOE Office of Environmental Management (United States)