Published August 21, 1997
| Version v1
Journal article
Statistical analysis and optimization of delay line chains for pixel readout electronics
Creators
- 1. Istituto Nazionale di Fisica Nucleare, Bari (Italy)
- 2. Bari Univ. (Italy). Dipt. di Elettrotecnica ed Elettronica
- 3. European Organization for Nuclear Research, Geneva (Switzerland)
Description
An analytic model of the variance of the delay given by the delay line integrated in the Omega3/LHC1 pixel readout chip is proposed and verified with experimental data. This model can be used to further tune the design in order to maximise delay uniformity, thus optimising pixel detector time resolution. (orig.)
Additional details
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 395
- Journal Issue
- 3
- Journal Page Range
- p. 318-323.
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- 3. international workshop on semiconductor pixel detectors for particles and X-rays.
- Dates
- 24-28 Mar 1996.
- Place
- Bari (Italy).
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 28076502
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DELAY CIRCUITS; OPTIMIZATION; POSITION SENSITIVE DETECTORS; READOUT SYSTEMS; STATISTICS; TIME RESOLUTION
- Descriptors DEC
- ELECTRONIC CIRCUITS; MATHEMATICS; MEASURING INSTRUMENTS; RADIATION DETECTORS; RESOLUTION; TIMING PROPERTIES
Optional Information
- Notes
- 5 refs.