Indoor 222Rn measurements using an activated charcoal detector

  • 1. Laboratory for Radiopharmaceutical Chemistry, Kyoritsu College of Pharmacy, Shibakoen, Minato-ku, Tokyo (Japan)
  • 2. Department of Environmental Science, Otsuma Women's University, Karakida, Tama-city, Tokyo (Japan)

Description

A commercially available activated charcoal detector for measuring 222Rn activity concentrations in air was calibrated with known amounts of 222Rn and examined in terms of air luminescence counts and interferences from 220Rn and 219Rn. The results for conditions normally encountered indoor indicate that the detector is simple and reliable. The method has been applied to assay indoor 222Rn activity concentrations in 387 homes in Tokyo and the adjacent four prefectures, which ranged from 0.7 to 140 Bq/m3 and averaged 22.7 Bq/m3

Additional details

Identifiers

PII
S0969804397101518;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
50
Journal Issue
3
Journal Page Range
p. 561-565
ISSN
0969-8043
CODEN
ARISEF

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
34015111
Subject category
S07: ISOTOPES AND RADIATION SOURCES;
Descriptors DEI
ACTIVATED CARBON; CALIBRATION; CHARCOAL; INDOOR AIR CONTAMINATION; RADIATION DETECTORS; RADON 222
Descriptors DEC
ADSORBENTS; ALPHA DECAY RADIOISOTOPES; CARBON; CONTAMINATION; DAYS LIVING RADIOISOTOPES; ELEMENTS; EVEN-EVEN NUCLEI; HEAVY NUCLEI; ISOTOPES; MEASURING INSTRUMENTS; NONMETALS; NUCLEI; RADIOISOTOPES; RADON ISOTOPES