Published March 2001
| Version v1
Report
Open
Seismic verification of mechanical and electrical components installed on WWER-type nuclear power plants using earthquake experience data
- 1. Stevenson and Associates, Pilsen (Czech Republic)
- 2. Westinghouse (Czech Republic)
Description
The purpose of this presentation is to describe the modified GIP titled as GIP-WWER which can be used to verify seismic adequacy of the safe shutdown mechanical and electrical equipment and also distribution systems of operating or constructed WWER-type NPPs, namely WWER-440/213 type NPPs. (author)
Files
32012666.pdf
Files
(495.5 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:4c808851f0d29d1d8acfa3a73bff7220
|
495.5 kB | Preview Download |
Additional details
Publishing Information
- Imprint Title
- Seismic evaluation of existing nuclear facilities. Proceedings of the SMiRT-14 post conference seminar no. 16
- Imprint Pagination
- 467 p.
- Journal Page Range
- p. 391-410
- ISSN
- 1011-4289
- Report number
- IAEA-TECDOC--1202
Conference
- Title
- SMiRT-14 post conference seminar no. 16 on seismic evaluation of existing nuclear facilities
- Dates
- 25-27 Aug 1997
- Place
- Vienna (Austria)
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 32012666
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- EARTHQUAKES; ELECTRICAL EQUIPMENT; MECHANICAL STRUCTURES; REACTOR SAFETY; REACTOR SHUTDOWN; SEISMIC ISOLATION; WWER TYPE REACTORS
- Descriptors DEC
- ENRICHED URANIUM REACTORS; EQUIPMENT; POWER REACTORS; PWR TYPE REACTORS; REACTORS; SAFETY; SEISMIC EVENTS; SHUTDOWN; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 29 refs, 2 figs, 2 tabs