Description
The stress corrosion susceptibility of Type 5083 aluminum--magnesium alloy in plate form and press-formed shapes was determined in the short transverse direction. C-ring type specimens were exposed to alternate immersion in a sodium chloride solution. The test equipment and procedure, with several innovative features, are described in detail. Statistical test results are listed for seven thermomechanical conditions. A certain processing scheme was shown to yield a work-strengthened part that is not sensitized with respect to stress corrosion cracking
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 18 p.
- Report number
- RFP--2645
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 10447996
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- ALUMINIUM BASE ALLOYS; CRACKS; HIGH TEMPERATURE; INTERGRANULAR CORROSION; MAGNESIUM ALLOYS; MATERIALS TESTING; MEASURING METHODS; MEDIUM TEMPERATURE; SODIUM CHLORIDES; STRESS CORROSION
- Descriptors DEC
- ALKALI METAL COMPOUNDS; ALLOYS; ALUMINIUM ALLOYS; CHEMICAL REACTIONS; CHLORIDES; CHLORINE COMPOUNDS; CORROSION; HALIDES; HALOGEN COMPOUNDS; SODIUM COMPOUNDS; TESTING