Published 2013 | Version v1
Journal article

Protection against ionizing radiation by leaded glass googles during interventional cardiology

  • 1. Tecnologia Medica, Facultad de Ciencias, Pontificia Universidad Catolica de Valparaiso, Valparaiso (Chile)
  • 2. Clinica Renaca S.A, Vina del Mar (Chile)
  • 3. Departamento de Dosimetria de la Comision Chilena de Energia Nuclear, Santiago (Chile)
  • 4. Medical Physics and Applied radiation sciences department, McMaster University (Canada)
  • 5. Escuela de Medicina, Facultad de Medicina, Universidad de Valparaiso, Valparaiso (Chile)
  • 6. Unidad de Hemodinamica Hospital Dr. Gustavo Fricke de Vina del Mar (Chile)
  • 7. Escuela de Tecnologia Medica, Facultad de Salud, Universidad Santo Tomas (Chile)
  • 8. Departamento de Estadistica, Facultad de Ciencias, Universidad de Valparaiso (Chile)

Description

Background: It is not known whether leaded glass goggles with 0.25 mm Pb equivalency, used in interventional cardiology procedures, attenuate radiation below the levels established by the latest recommendation of the International Commission on Radiological Protection (ICRP). Aim: To assess if the degree of attenuation of the secondary ionizing radiation achieved by the use of 0.25 mm Pb leaded glass goggles, in occupationally exposed workers in interventional cardiology procedures, meets the latest ICRP recommendations. Material and Methods : A prospective investigation was carried out to compare the eye exposure to secondary ionizing radiation received by occupationally exposed personnel in a 9 months period. A set of two thermo luminescent dosimeters was arranged in the front and back of leaded glass goggles in a cohort of seven members of an interventional cardiology service, exposed to 1057 consecutive procedures. Results:The monthly dose equivalent measurement performed in front of the goggles ranged between 1.1 and 6.5 mSv,for paramedics and interventional cardiologists. The radiation measured in the back of the glass varied between 0.66 and 2.75 mSv,respectively.The degree of attenuation of the dose at eye level ranged from 40% to 57.7%,respectively. The projected annual exposure would reach 33 mSv for the interventional cardiologist. Conclusions: With a similar load of work and wearing 0.25 mm Pb equivalent glass goggles, interventional cardiologists will exceed the crystalline equivalent dose limit recommended by the ICRP (20 mSv/year averaged over the past 5 years)

Additional details

Additional titles

Original title (Spanish)
Es suficiente la proteccion otorgada por gafas plomadas en cardiologia intervencionista?

Publishing Information

Journal Title
Revista Medica de Chile
Journal Volume
141
Journal Issue
1
Journal Page Range
p. 63-69
ISSN
0034-9887

INIS

Country of Publication
Chile
Country of Input or Organization
Chile
INIS RN
45079543
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
CRYSTALLINE LENS; IONIZING RADIATIONS; NUCLEAR MEDICINE; OCCUPATIONAL EXPOSURE; RADIATION DOSES; RADIOLOGY
Descriptors DEC
BODY; DOSES; EYES; FACE; HEAD; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATIONS; SENSE ORGANS