Published January 1985 | Version v1
Journal article

Isodose curves through films

  • 1. Hospital Municipal de Campinas (Brazil)
  • 2. Nucleon Radioterapia e Fisica Medica, Sorocaba (Brazil)
  • 3. Instituto de Radioterapia Osvaldo Cruz, Sao Paulo (Brazil)
  • 4. Hospital de Caridade S.V. de Paula, Jundiai (Brazil)

Description

Information about the beam profile of 4 MV X-rays through irradiation of radiographic films is presented. The films were irradiated in parallel to the central axis, within tissue-like phantom and in conditions of clinical application. The conclusion is that the method does not supply absolute values of percentage depth dose over points outside of beam bounds, but throughout the corrections it may be of great utility in radiation dosimetry. (Author)

Abstract (Portuguese)

Apresentam-se, a partir de irradiacoes de peliculas radiograficas, informacoes sobre o perfil de feixes de radiacao de raios X de 4 MV. Os filmes foram irradiados paralelamente ao feixe central, dentro de material simulador de tecido e nas condicoes usuais de trabalho. Conclui-se que o metodo, apesar de nao fornecer valores absolutos de porcentagens de dose profunda na periferia dos feixes, pode, atraves de correcoes, ser de grande utilidade na dosimetria clinica. (Autor)

Additional details

Additional titles

Original title (Portuguese)
Curvas de isodose com filmes

Publishing Information

Journal Title
Radiol. Bras.
Journal Volume
18
Journal Issue
1
Series
Radiol. Bras.
Journal Page Range
100-102
ISSN
0100-3984
CODEN
RDBRA