Published August 2007 | Version v1
Journal article

Internal dose estimation for occupational exposure to 241Am in an incident during decommissioning

  • 1. China Academy of Engineering Physics, Institute of Nuclear Physics and Chemistry, Mianyang (China)

Description

241Am in urine of four workers who worked in an unexpected accident of 241Am during decommissing was mensurated, and multiple ingestion mode was adopted. The result showed that the maximum 241Am intake was 349 Bq and the maximum effective dose was 9.4 mSv, both below annual intake limit 740 Bq and annul dose limit 20 mSv. (authors)

Additional details

Publishing Information

Journal Title
Radiation Protection Bulletin
Journal Volume
27
Journal Issue
4
Journal Page Range
p. 17-19
ISSN
1004-6356

Optional Information

Notes
1 fig., 2 tabs., 6 refs.