Published January 2001 | Version v1
Journal article

Study of sources of external exposure to plant personnel at Kaiga Generating Station

  • 1. Health Physics Div., Bhabha Atomic Research Centre, Mumbai (India)

Description

Kaiga Generating Station consists of two Pressurised Heavy Water Reactors of 220 MWe capacity each. Unit-2 started power generation from December 2, 1999. Identification and quantification of radionuclides present in the work areas during reactor operation and shut down is essential for incorporating measures to achieve ALARA exposure to plant personnel. A study was conducted to identify the radionuclides present in work areas to meet this objective. The results indicate that the activation products, which were not anticipated during the design, contribute more than expected dose rates in the work environment. The techniques adopted for identification, quantification and estimation of dose contribution by different gamma emitting isotopes in the work environment are discussed in this report. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection and Environment
Journal Volume
24
Journal Issue
1-2,suppl
Journal Page Range
p. S107-S112
ISSN
0972-0464

Conference

Title
25. satellite meeting of international conference on radiation safety aspects and environment impact assessment of nuclear power plants
Acronym
IARP-IC.2K1
Dates
26-27 Feb 2001
Place
Kaiga (India)

Optional Information

Notes
3 refs., 4 figs., 2 tabs.