Towards a simplified fluid-sensitive MRI protocol in small joints of the hand in early arthritis patients. Reliability between modified Dixon and regular Gadolinium enhanced TSE fat saturated MRI-sequences
Creators
- 1. Department of Rheumatology, Erasmus Medical Center, Rotterdam (Netherlands)
- 2. Department of Rheumatology, Leiden University Medical Center, Leiden (Netherlands)
- 3. Department of Radiology, Leiden University Medical Center, Leiden (Netherlands)
Description
MRI of small joints plays an important role in the early detection and early treatment of rheumatoid arthritis. Despite its sensitivity to demonstrate inflammation, clinical use is hampered by accessibility, long scan time, intravenous contrast, and consequent high costs. To improve the feasibility of MRI implementation in clinical practice, we introduce a modified Dixon sequence, which does not require contrast and reduces total acquisition time to 6 min. Because the reliability in relation to conventional MRI sequences is unknown, we determined this. In 29 consecutive early arthritis patients, coronal and axial T2-weighted modified Dixon acquisitions on 3.0 T MRI scanner were acquired from metacarpophalangeal 2-5 to the wrist, followed by the standard contrast-enhanced protocol on 1.5 T extremity MRI. Two readers scored osteitis, synovitis and tenosynovitis (summed as total MRI-inflammation), and erosions (all summed as total Rheumatoid Arthritis MRI Score (RAMRIS)). Intraclass correlation coefficients (ICCs) between readers, and comparing the two sequences, were studied. Spearman correlations were determined. Performance between readers was good/excellent. Comparing modified Dixon and conventional sequences revealed good/excellent reliability: ICC for total MRI-inflammation score was 0.84 (95% CI:0.70-0.92), for erosions 0.90 (95% CI:0.79-0.96), and for the total RAMRIS score 0.88 (95% CI:0.77-0.94). The scores of total MRI-inflammation, total erosions, and total RAMRIS were highly correlated (ρ = 0.80, ρ = 0.81, ρ = 0.82, respectively). The modified Dixon protocol is reliable compared to the conventional MRI protocol, suggesting it is accurate to detect MRI inflammation. The good correlation may be the first step towards a patient-friendly, short and affordable MRI protocol, which can facilitate the implementation of MRI for early detection of inflammation in rheumatology practice.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00256-022-04238-8Additional details
Identifiers
Publishing Information
- Journal Title
- Skeletal Radiology
- Journal Volume
- 52
- Journal Issue
- 6
- Journal Page Range
- p. 1193-1202
- ISSN
- 0364-2348
- CODEN
- SKRADI
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 54059644
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BONE JOINTS; COMPARATIVE EVALUATIONS; CONTRAST MEDIA; CORRELATIONS; COST; DATA COMPILATION; GADOLINIUM; HANDS; IMAGE PROCESSING; IMAGE SCANNERS; INFLAMMATION; MAGNETIC FIELDS; NMR IMAGING; RELAXATION TIME; RELIABILITY; RHEUMATIC DISEASES; SENSITIVITY; WEIGHTING FUNCTIONS
- Descriptors DEC
- ARMS; BODY; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; DISEASES; ELEMENTS; EVALUATION; FUNCTIONS; INFORMATION; LIMBS; METALS; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; RARE EARTHS; SKELETON; SYMPTOMS