Published May 2014 | Version v1
Miscellaneous

Basic Design Study on 1-MV Electrostatic Accelerator for ion irradiation

  • 1. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

Description

The KOMAC (KOrea Multi-purpose Accelerator Complex) has electrostatic ion accelerators whose terminal voltages are less than 100kV. To extend ion beam irradiations with higher energy ions for industrial purposes, an electrostatic accelerator of 1-MV terminal voltage should have been studied. For industrial applications, the most important features of the accelerator are high current and high reliability for high irradiation dose and high through-put with high current and long irradiation time. The basic study on 1-MV electrostatic ion accelerator for industrial applications has been done. The key components are a high voltage power supply, an ion source, and an accelerating column. The feasibility study for fabrication is being performed. Especially the R and D for ion source is required. The 1-MV ion accelerator will be constructed with domestic companies and installed in the beam application research building, which is under construction in the site of KOMAC at Gyeongju

Part of:
Proceedings of the KNS 2014 spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Proceedings of the KNS 2014 spring meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[2 p.]

Conference

Title
2014 spring meeting of the KNS
Dates
28-30 May 2014
Place
Jeju (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
46050718
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
DESIGN; ELECTROSTATIC ACCELERATORS; FABRICATION; FEASIBILITY STUDIES; IRRADIATION; RELIABILITY; USES
Descriptors DEC
ACCELERATORS

Optional Information

Notes
2 refs, 7 figs, 1 tab