Published May 28, 2012
| Version v1
Journal article
Combined failure acoustical diagnosis based on improved frequency domain blind deconvolution
- 1. Faculty of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming, 650093 (China)
Description
According to gear box combined failure extraction in complex sound field, an acoustic fault detection method based on improved frequency domain blind deconvolution was proposed. Follow the frequency-domain blind deconvolution flow, the morphological filtering was firstly used to extract modulation features embedded in the observed signals, then the CFPA algorithm was employed to do complex-domain blind separation, finally the J-Divergence of spectrum was employed as distance measure to resolve the permutation. Experiments using real machine sound signals was carried out. The result demonstrate this algorithm can be efficiently applied to gear box combined failure detection in practice.
Availability note (English)
Available from http://dx.doi.org/10.1088/1742-6596/364/1/012078Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Physics. Conference Series (Online)
- Journal Volume
- 364
- Journal Issue
- 1
- Journal Page Range
- [7 p.]
- ISSN
- 1742-6596
Conference
- Title
- 25. International congress on condition monitoring and diagnostic engineering
- Acronym
- COMADEM 2012
- Dates
- 18-20 Jun 2012
- Place
- Huddersfield (United Kingdom)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 43100361
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALGORITHMS; DISTANCE; FAILED ELEMENT DETECTION; FAILURES; GEARS; MECHANICAL ENGINEERING; MODULATION; SAFETY ENGINEERING; SIGNALS; SOUND WAVES; SYSTEM FAILURE ANALYSIS
- Descriptors DEC
- DETECTION; ENGINEERING; MACHINE PARTS; MATHEMATICAL LOGIC; SYSTEMS ANALYSIS