Dynamic analyses and control systems for steam generators in LMFBRs

  • 1. Mitsubishi Atomic Power Industries, Inc., Tokyo (Japan)

Description

The steam generators (SG) of LMFBRs are divided into once-through-, and recirculating-type. The use of the two different SGs in prototype-LMFBRs design has been influenced by the conventional technique of fossil-fired boilers, but from a control system and plant equipment operations point of view, the type of SG has not been selected, because of no comparative evaluation of dynamic behaviour associated with the two-types. In addition, the operational requirements for post scram control of residual heat removal via SG systems is considered to be an important factor where a choice is made of SG-type. In this paper, a control-, and interlock-system of each of the SG cycles is proposed on the basis of dynamic analysis of recirculating versus once-through type, with regard to post scram control and severity of thermal transient. (author)

Additional details

Publishing Information

Publisher
British Nuclear Energy Society.
Imprint Place
London
ISBN
0 7277 0095 2
Imprint Title
Boiler dynamics and control in nuclear power stations 2
Imprint Pagination
430 p.
Journal Page Range
p. 273-280.

Conference

Title
2. international conference on boiler dynamics and control in nuclear power stations.
Dates
23 - 25 Oct 1979.
Place
Bournemouth, UK.

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
12585905
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AFTER-HEAT REMOVAL; CONTROL SYSTEMS; DYNAMIC PROGRAMMING; LMFBR TYPE REACTORS; MATHEMATICAL MODELS; REACTOR OPERATION; SCRAM; STEAM GENERATORS; TRANSIENTS
Descriptors DEC
BOILERS; BREEDER REACTORS; EPITHERMAL REACTORS; FAST REACTORS; FBR TYPE REACTORS; LIQUID METAL COOLED REACTORS; OPERATION; REACTOR SHUTDOWN; REACTORS; VAPOR GENERATORS