Published October 2016 | Version v1
Journal article

Pharmacokinetics, Safety, and Efficacy of Chemoembolization with Doxorubicin-Loaded Tightly Calibrated Small Microspheres in Patients with Hepatocellular Carcinoma

  • 1. National and Kapodistrian University of Athens, Medical School, Evgenidion Hospital, 2nd and 1st Department of Radiology (Greece)
  • 2. National and Kapodistrian University of Athens, Medical School, Hippokration General Hospital, 2nd Department of Internal Medicine, Hepatology (Greece)
  • 3. Foundation Biomedical Research of Academy of Athens (FBRA) (Greece)

Description

PurposeThis study examines safety, efficacy, and pharmacokinetics of chemoembolization with loadable microspheres ≤100 μm for hepatocellular carcinoma.Materials and MethodsA pilot safety study was performed in 19 patients with size and dose escalation and then 52 patients were enrolled prospectively and randomly assigned to chemoembolization with TANDEM™ loaded with 150 or 100 mg of doxorubicin.ResultsThe mean diameter of the tumors was 7.28 ± 2.09 cm (range 4–12) and distribution dominant/multiple 51.9/48.1 %. Child A/B distribution was 32/20 (61.5/38.5 %) and etiology HBV/HCV/HBV/HCV-hemochromatosis was 61.6/9.6/9.6/15.4 %. Twenty-five patients were assigned in the low and 27 in the high loading group. There was 1.92 % thirty-day mortality due to lesion rupture. Biliary damage was seen in 3 patients (5.7 %) in the high loading. Mean maximum plasma concentration of doxorubicin Cmax ± SD was 284.9 ± 276.2 ng/mL for the high and 108.5 ± 77.6 ng/mL for the low loading (p < 0.001). According to m-RECIST overall objective response after two sessions reached 61.22 and 63.82 % at 6 months. Notably, complete target lesion response (CR) after the second session was observed in 28.57 % and maintained in 23.40 % at 6 months. No statistical differences in the local response rates were observed between the two loading groups. Overall survival (OS) at 6 months, 1 , 2, and 3 years was 98.08, 92.3, 88.46, and 82.6 %, respectively. OS and Progression-Free Survival did not demonstrate statistical significance between the two loading groups.ConclusionInitial evidence shows that (a) TANDEM™ achieves high rates of local response and mid-term survival, (b) high loading provides no clinical benefit and is associated with biliary toxicity.

Additional details

Identifiers

Publishing Information

Journal Title
Cardiovascular and Interventional Radiology
Journal Volume
39
Journal Issue
10
Journal Page Range
p. 1379-1391
ISSN
0174-1551
CODEN
CAIRDG

Optional Information

Copyright
Copyright (c) 2016 Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE)
Notes
http://www.springer-ny.com