Research to improvement of the definition of 210 Po and 210 Pb in deposition

Description

Investigation to the improvement of the determination of 210Po and 210Pb in deposition. The results of the determination of 210Po and 210Pb in deposition in 1995 do not meet the criteria specified. The chemical recovery of the 208Po tracer added is by many analyses less than the required 50%. The cause of the poor chemical recovery is investigated. This report describes the execution of the investigation and the results. The investigation has led to the improvement of the determination of 210Po and 210Pb in deposition. 12 refs

Availability note (English)

Available from RIVM, P.O. Box 1, 3720 BA Bilthoven (NL)

Additional details

Additional titles

Original title (Dutch)
Onderzoek naar de verbetering van de bepaling van

Publishing Information

Imprint Pagination
14 p.
Report number
RIVM--610220001

Optional Information

Contract/Grant/Project number