Pulsed high-current accelerator with matching transformer

  • 1. NII Vysokikh Napryazhenij pri Tomskom Politekhnicheskom Univ., Tomsk (Russian Federation)

Description

The matching transformer with external magnetization located between the double-forming line (DFL) and diode node was applied for increasing the efficiency of the energy transfer stored in the DFL of the high-current electron accelerator into the electron beam. Saturation of the transformer core up to the line charge stage made it possible significantly to decrease the pre-pulse amplitude and its effect on the diode foil stability without application of the peaking discharge. The accelerator provides for obtaining the electron beam with the pulse energy of 200 J by the electrons kinetic energy of 500 keV and pulse duration of 60 ns

Abstract (Russian)

Для повышения эффективности передачи энергии, запасаемой в двойной формирующей линии (ДФЛ) сильноточного ускорителя электронов, в электронный пучок использован согласующий трансформатор с внешним подмагничиванием, размещенный между ДФЛ и диодным узлом. Насыщение сердечника трансформатора до стадии зарядки линии позволило значительно уменьшить амплитуду предымпульса и его влияние на стойкость анодной фольги без применения обостряющего разрядника. Ускоритель обеспечивает получение пучка электронов с энергией в импульсе 200 Дж при кинетической энергии электронов 500 кэВ и длительности импульса 60 нс

Additional details

Additional titles

Original title (Russian)
Импульсный сильноточный ускорител' с согласующим трансформатором

Publishing Information

Journal Title
Pribory i Tekhnika Ehksperimenta
Journal Issue
no.3
Journal Page Range
p. 130-134
ISSN
0032-8162
CODEN
PRTEAJ

Optional Information

Notes
4 refs., 5 figs.