Published October 2004
| Version v1
Journal article
Magnetic sensorless sensing of plasma position in the superconducting tokamak HT-7
Creators
- 1. Research Institute for Applied Mechanics, Kyushu University, Kasuga City (Japan)
- 2. Chinese Academy of Sciences, Hefei (China). Inst. of Plasma Physics
Description
Magnetic sensorless sensing experiments of the plasma horizontal position have been carried out in the superconducting tokamak HT-7. The horizontal position is calculated from the vertical field coil current and voltage without using signals of magnetic probes placed nearby a plasma. The calculations are focused on the ripple frequency component of the power supply. There is no drift problem with the time integration of magnetic probe signals. The error of the derived plasma position is lower than 2% of the plasma minor radius. (authors)
Additional details
Publishing Information
- Journal Title
- Plasma Science and Technology
- Journal Volume
- 6
- Journal Issue
- 5
- Journal Page Range
- p. 2459-2462
- ISSN
- 1009-0630
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 37107639
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ELECTRIC CURRENTS; ELECTRIC POTENTIAL; ERRORS; HT-7 TOKAMAK; MAGNETIC PROBES; PLASMA; POSITIONING; POWER SUPPLIES; SUPERCONDUCTING COILS; SUPERCONDUCTING MAGNETS
- Descriptors DEC
- CLOSED PLASMA DEVICES; CURRENTS; ELECTRIC COILS; ELECTRICAL EQUIPMENT; ELECTROMAGNETS; ELECTRONIC EQUIPMENT; EQUIPMENT; MAGNETS; PROBES; SUPERCONDUCTING DEVICES; THERMONUCLEAR DEVICES; TOKAMAK DEVICES
Optional Information
- Notes
- 5 figs., 3 refs.