Published November 7, 2006
| Version v1
Journal article
Efficient schemes for robust IMRT treatment planning
Creators
- 1. Industrial Engineering Department, University of Wisconsin, 1513 University Avenue, Madison, WI 53706 (United States)
- 2. Computer Sciences Department, University of Wisconsin, 1210 W Dayton Street, Madison, WI 53706 (United States)
Description
We use robust optimization techniques to formulate an IMRT treatment planning problem in which the dose matrices are uncertain, due to both dose calculation errors and interfraction positional uncertainty of tumour and organs. When the uncertainty is taken into account, the original linear programming formulation becomes a second-order cone program. We describe a novel and efficient approach for solving this problem, and present results to compare the performance of our scheme with more conventional formulations that assume perfect knowledge of the dose matrix
Availability note (English)
Available online at http://stacks.iop.org/0031-9155/51/5621/pmb6_21_016.pdf or at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/Additional details
Identifiers
- URL
- http://stacks.iop.org/0031-9155/51/5621/pmb6_21_016.pdf; http://www.iop.org/;
- DOI
- 10.1088/0031-9155/51/21/016;
- PII
- S0031-9155(06)16947-X;
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 51
- Journal Issue
- 21
- Journal Page Range
- p. 5621-5642
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38008658
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ERRORS; OPTIMIZATION; ORGANS; PERFORMANCE; PLANNING; RADIATION DOSES
- Descriptors DEC
- BODY; DOSES