Published 1984
| Version v1
Report
Czechoslovak system for X-ray and neutron nondestructive testing
Creators
- 1. Ustav Jaderneho Vyzkumu CSKAE, Rez (Czechoslovakia)
Description
The X-ray and neutron non-destructive testing system for welds and casts testing is developed. The 30-400 kV X-ray tube isotope source or a reactor with 107 n/cm2 X s thermal neutron flux is used as a radiation source. The object image gets to the television camera. Some system CAMAC modules are briefly described
Additional details
Additional titles
- Original title (no language)
- 11. Mezhdunarodnyj simpozium po yadernoj ehlektronike.
Publishing Information
- Imprint Title
- 11. International symposium on nuclear electronics
- Journal Page Range
- p. 317-320.
- Report number
- JINR-D--13-84-53
Conference
- Title
- 11. International symposium on nuclear electronics.
- Dates
- 6-12 Sep 1983.
- Place
- Bratislava (Czechoslovakia).
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 16038938
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CAMAC SYSTEM; IMAGES; NEUTRON RADIOGRAPHY; NONDESTRUCTIVE TESTING; QUALITY CONTROL; TELEVISION; X-RAY RADIOGRAPHY
- Descriptors DEC
- CONTROL; MATERIALS TESTING; TESTING
Optional Information
- Notes
- Imprint:11. Mezhdunarodnyj simpozium po yadernoj ehlektronike.