Published February 4, 2022 | Version v1
Journal article

I-124 PET/CT image-based dosimetry in patients with differentiated thyroid cancer treated with I-131. Correlation of patient-specific lesional dosimetry to treatment response

  • 1. MedStar Health Research Institute. Division, Nuclear Medicine Research, Hyattsville, MD (United States)
  • 2. Johns Hopkins University, School of Medicine. Radiological Physics Division Department of Radiology and Radiological Sciences, Baltimore, MD (United States)
  • 3. MedStar Washington Hospital Center. Division of Nuclear Medicine, Washington, D.C. (United States)

Description

Purpose

The objective of this study is to evaluate the lesion absorbed dose (AD), biological effective dose (BED), and equivalent uniform dose (EUD) to clinical-response relationship in lesional dosimetry for 131I therapy.

Methods

Nineteen lesions in four patients with metastatic differentiated thyroid cancer (DTC) were evaluated. The patients underwent PET/CT imaging at 2 h, 24 h, 48 h, 72 h, and 96 h post administration of ∼ 33-65 MBq (0.89-1.7 mCi) of 124I before undergoing 131I therapy. The 124I PET/CT images were used to perform dosimetry calculations for 131I therapy. Lesion dose-rate values were calculated using the time-activity data and integrated over the measured time points to obtain AD and BED. The Geant4 toolkit was used to run Monte Carlo on spheres the same size as the lesions to estimate EUD. The lesion AD, BED, and EUD values were correlated with response data (i.e. change in lesion size pre- and post-therapy): complete response (CR, i.e. disappearance of the lesion), partial response (PR, i.e. any decrease in lesion length), stable disease (SD, i.e., no change in length), and progressive disease (PD, i.e., any increase in length).

Results

The lesion responses were CR and PR (58%, 11/19 lesions), SD (21%, 4/19), and PD (21%, 4/19). For CR and PR lesions, the ADs, BEDs and EUDs were > 75 Gy for 82% (9/11) and < 75 Gy for 18% (2/11). The ADs and BEDs were < 75 Gy for SD and PD lesions.

Conclusion

By performing retrospective dosimetry calculations for 131I therapy based on 124I PET/CT imaging, we evaluated the correlation of three dosimetric quantities to lesional response. When lesion AD, BED, and EUD values were > 75 Gy, 47% (9/19) of the lesions had a CR or PR. The AD, BED, and EUD values for SD and PD lesions were < 75 Gy. The data presented herein suggest that the greater the lesion AD, BED, and/or EUD, the higher the probability of a therapeutic response to 131I therapy. (author)

Additional details

Identifiers

Publishing Information

Journal Title
Annals of Nuclear Medicine
Journal Volume
36
Journal Issue
3
Journal Page Range
p. 213-223
ISSN
0914-7187
CODEN
ANMEEX

Optional Information

Copyright
Copyright (c) 2022 © The Author(s) under exclusive licence to The Japanese Society of Nuclear Medicine 2022