Application of γ-spectrometer of slow summary coincidences for 130I measurument on neutron activation determination of 129I in environmental samples
Description
The possibility to use γ-spectrometer of slow summary coincidences for measuring 129I (by the product of its activation 130I) in the mixture with stable 127I is investigated. It is shown that the use of the spectrometer improves the determination limit, detection limit and sensitivity of the method by nearly two orders
Additional details
Additional titles
- Original title (Russian)
- Применение γ-спектрометра медленных суммарных совпадений для измерения
Publishing Information
- Journal Title
- Radiokhimiya
- Journal Volume
- 28
- Journal Issue
- 3
- Series
- Radiokhimiya.
- Journal Page Range
- 390-393
- ISSN
- 0033-8311
- CODEN
- RADKA
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- USSR
- INIS RN
- 18034887
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Descriptors DEI
- GAMMA SPECTRA; GAMMA SPECTROMETERS; IODINE 129; IODINE 130; NEUTRON ACTIVATION ANALYSIS; SENSITIVITY
- Descriptors DEC
- ACTIVATION ANALYSIS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CHEMICAL ANALYSIS; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTO; IODINE ISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MEASURING INSTRUMENTS; MINUTES LIVING RADIOISOTOPES; NONDESTRUCTIVE ANALYSIS; NUCLEI; ODD-EVEN NUCLEI; ODD-ODD NUCLEI; RADIOISOTOPES; SPECTRA; SPECTROMETERS; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- For English translation see the journal Soviet Radiochemistry (USA).