Published 1996 | Version v1
Book

Steam generator feedwater nozzle transition piece replacement experience at Salem Unit 1

  • 1. Public Service Electric and Gas Co., Hancocks Bridge, NJ (United States)
  • 2. Structural Integrity Associates, Inc., San Jose, CA (United States)
  • 3. Welding Services, Inc., Atlanta, GA (United States)

Description

Cracking of steam generator feedwater piping adjacent to the feedwater nozzles has been a recurring problem since 1979 at Salem Unit 1 owned and operated by Public Service Electric and Gas Company. In addition to the cracking problem, erosion-corrosion at the leading edge of the feedwater nozzle thermal sleeve was also observed in 1992. To provide a long-term solution for the pipe cracking and thermal sleeve erosion-corrosion problems, a unique transition piece forging was specially designed, fabricated, and installed for each of the four steam generators during the 1995 outage. This paper discusses the design, fabrication, and installation of the transition piece forgings at Salem Unit 1, and the experiences gained from this project. It is believed that these experiences may help other utilities when planning similar replacements in the future

Additional details

Publishing Information

Publisher
American Society of Mechanical Engineers.
Imprint Place
New York, NY (United States)
ISBN
0-7918-1780-6
Imprint Title
Integrity of structures, and fluid systems, hazardous release protection, piping and pipe supports, and pumps and valves. PVP-Volume 333
Imprint Pagination
267 p.
Journal Page Range
p. 13-19.

Conference

Title
American Society of Mechanical Engineers (ASME) pressure vessels and piping conference.
Dates
21-26 Jul 1996.
Place
Montreal (Canada).

Optional Information

Secondary number(s)