Published August 2017 | Version v1
Miscellaneous

Proposal of maintenance management of nuclear power plants at R and D stage by taking account of their features. (4) Case study on sodium valves

  • 1. Japan Atomic Energy Agency, Oarai, Ibaraki (Japan)
  • 2. Japan Atomic Energy Agency, Tsuruga, Fukui (Japan)

Description

A maintenance management suitable to nuclear power plants (NPP) at R and D stage was discussed. Objectives of maintenance management of NPP at R and D stage were first clarified. Next, applicability of codes for maintenance management of commercial NPP to NPP at R and D stage was discussed. Then, requirements and consideration for maintenance management of NPP at R and D stage was proposed. In this paper, maintenance program for sodium valves are investigated. (author)

Part of:
Proceedings of the 14th annual meeting of Japan Society of Maintenology

Additional details

Additional titles

Original title (Japanese)
研究開発段階発電用原子炉の特徴を考慮した保守管理の提案.(4) ナトリウム弁の事例

Publishing Information

Imprint Title
Proceedings of the 14th annual meeting of Japan Society of Maintenology
Imprint Pagination
580 p.
Journal Page Range
p. 367-370

Conference

Title
14. annual meeting of Japan Society of Maintenology
Dates
2-4 Aug 2017
Place
Matsuyama, Ehime (Japan)

Optional Information

Notes
7 refs., 12 figs. Imprint:#65E5##672C##4FDD##5168##5B66##4F1A##7B2C#14#56DE##5B66##8853##8B1B##6F14##4F1A##8981##65E8##96C6#