Published 1988 | Version v1
Book

Ultimate load model test for Sizewell 'B' primary containment

Creators

  • 1. National Nuclear Corp. Ltd., Knutsford (UK)

Description

This paper considers the factors influencing the adoption of an ultimate load factor for the Sizewell 'B' PWR primary containment structure. As part of the validation process for the ultimate load analysis method, a proposal has been made by Nuclear Design Associates to build and test a 1/10th scale model of the containment structure, which would proceed following the granting of section 2 consent for Sizewell 'B'. The modelling principles, construction method and test proposals are examined in some detail. The proposal is currently being considered by the CEGB's Project Management Team. (author)

Additional details

Publishing Information

Publisher
Cambridge University Press.
Imprint Place
Cambridge (UK)
ISBN
0 521 35130 8
Imprint Title
Nuclear containment
Imprint Pagination
457 p.
Journal Page Range
p. 5-19.

Conference

Title
International conference on nuclear containment.
Dates
6-8 Apr 1987.
Place
Cambridge (UK).