Published November 21, 1996 | Version v1
Journal article

Maze design of a gantry room for proton therapy

  • 1. Politecnico di Milano (Italy). Ist. di Ingegneria Nucleare
  • 2. Universita degli Studi di Milano, Dipartimento di Fisica and INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy)
  • 3. CERN, 1211 Geneve 23 (Switzerland)

Description

Monte Carlo simulations with the LCS code were performed for the design of the access maze of an isocentric gantry room for proton therapy. The double distributions of secondary neutrons, produced by 250 MeV protons in the gantry structural materials and in the patient, were determined at the treatment room access for different irradiation directions. Neutron transport was simulated in a three-leg maze of various lengths. The secondary photons produced by neutrons in the maze walls were taken into account. The simulation results were fitted by analytical expressions based on the solution of the Hubbell integral for a rectangular radiation source. Some simulations were also performed with the FLUKA code for comparison. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
382
Journal Issue
3
Journal Page Range
p. 573-582.
ISSN
0168-9002
CODEN
NIMAER