Published June 2, 2000 | Version v1
Journal article

The FADC readout of the MAGIC telescope

  • 1. Max-Planck Institut fuer Physik, Foehringer Ring 6, 80805 Munich (Germany)

Description

The MAGIC Telescope will use FADCs to sample the camera pixel signals. This allows to analyze features of the Cherenkov time pulses with ∼1 ns resolution and to minimize data taking deadtime and noise. Here we report on the first tests of a 300 MHz FADC 32-channel unit and on some special solutions for enlarging the signal's dynamical range. In the long run MAGIC will be provided with >1 GHz FADCs in order to profit from the full speed capabilities of the PMs in use [1 ns FWHM]

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
515
Journal Issue
1
Journal Page Range
p. 363-367
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
26. International cosmic ray conference
Acronym
ICRC 1999
Dates
17-25 Aug 1999
Place
Salt Lake City, UT (United States)

Optional Information

Notes
(c) 2000 American Institute of Physics.
Collaborations
MAGICT collaboration