Published 1994
| Version v1
Book
Neutron dosimetry and activation on the tokamak Tore-Supra
Description
In Tore-Supra, neutron productions up to 1020 neutrons/year are expected. Calculations based on 1-D and 3-D codes have been made before the assembly phase. A strategy has been established to reconcile high neutron levels with the needs of an experimental device, i.e. access to the tokamak. Operation at low power (8.5 1016 neutrons) has allowed an initial set of measurements, which has been compared to the calculations. Quite good agreement is observed, especially for fast neutrons. A difference for slow neutrons is attributed to a small quantity of boron added in the concrete wall surrounding the experiment and to safety factors in the computations
Additional details
Publishing Information
- Publisher
- American Society for Testing and Materials.
- Imprint Place
- Philadelphia, PA (United States)
- ISBN
- 0-8031-1899-6
- Imprint Title
- Reactor dosimetry. ASTM STP 1228
- Imprint Pagination
- 871 p.
- Journal Page Range
- p. 792-799.
Conference
- Title
- 8. ASTM-EURATOM symposium on reactor dosimetry.
- Dates
- 29 Aug - 3 Sep 1993.
- Place
- Vail, CO (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26065159
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BIOLOGICAL SHIELDS; COBALT 58; NEUTRON DOSIMETRY; RADIATION DOSES; RADIATION PROTECTION; THERMOLUMINESCENT DOSEMETERS; TORE SUPRA TOKAMAK; VACUUM SYSTEMS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; CLOSED PLASMA DEVICES; COBALT ISOTOPES; DAYS LIVING RADIOISOTOPES; DOSEMETERS; DOSIMETRY; ELECTRON CAPTURE RADIOISOTOPES; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; NUCLEI; ODD-ODD NUCLEI; RADIOISOTOPES; SHIELDS; THERMONUCLEAR DEVICES; TOKAMAK DEVICES
Optional Information
- Secondary number(s)
- CONF-930809--.