Ultrasonic examination of thin iridium hemispheres for the multihundred watt heat source

Description

An ultrasonic method was developed for nondestructive inspection of the structural integrity of the 20-mil (0.0508-cm) thick iridium hemispheres that are used in the fabrication of Multihundred Watt (MHW) radioisotopic heat sources. A hemisphere was considered unacceptable if a back-surface ultrasonic response change was equivalent to that obtained from a 0.010-in. (0.0254-cm) diameter flat-bottomed hole in the standard. Flaws were detected in hemispheres made by the initial fabrication process. Typical flaws found ultrasonically in these units and revealed by metallography are shown. Hemispheres formed after a change to a different fabrication process were free of flaws