Published December 2021 | Version v1
Journal article

A fluorescent sensor recognized by the FA1 site for highly sensitive detection of HSA

  • 1. Gansu Key Laboratory of Biomonitoring and Bioremediation for Environmental Pollution, School of Life Sciences, Lanzhou University, Lanzhou, 730000 (China)

Description

Highlights: • An HSA response sensor DCM-ML via FA1 recognition was demonstrated by both displacement experiments and molecular docking. • The study provided deep insight into the sensing mechanism of sensor DCM-ML towards HSA. • No similar FA1 site in BSA was revealed for the first time, explaining much lower fluorescence response of DCM-ML to BSA. Human serum albumin (HSA), as the most abundant protein in blood plasma, plays a crucial role in many physiological processes. The abnormal HSA level in serum or in urine is often associated with various diseases. Therefore, to achieve highly sensitive and selective quantification of HSA is of great importance for disease diagnosis and preventive medicine. Herein, an HSA-selective light-up fluorescent sensor, DCM-ML, was successfully developed for quantitative detection of HSA. DCM-ML exhibited good (photo-) stability and strong fluorescence enhancement around 630 nm in the presence of HSA in complex samples containing numerous biological analytes. Upon addition of HSA into DCM-ML containing solution, a good linear relationship (R2 > 0.99) between the fluorescence intensity of DCM-ML and HSA concentration from 0 to 0.08 mg/mL was obtained with the detection limit of 0.25 μg/mL. The sensing mechanism of the sensor towards HSA was demonstrated to be via recognition in the fatty acid site 1 (FA1), instead of the most reported binding sites (Sudlow I and II) in HSA, for the first time, by both the displacement experiments and molecular docking simulation. Thus, DCM-ML can also be assumed as a potential FA1 site-binding marker for examining drugs binding to the FA1 site in HSA. At last, the utilization of sensor DCM-ML for quantification and validation of HSA in urine samples and cell culture medium was effectively demonstrated. Therefore, the development of DCM-ML should find great application potentials in the fields of analytical chemistry and clinical medicine as a highly sensitive HSA sensor.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.aca.2021.339201

Additional details

Identifiers

DOI
10.1016/j.aca.2021.339201;
PII
S0003267021010278;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
1188
Journal Page Range
vp.
ISSN
0003-2670
CODEN
ACACAM

Optional Information

Copyright
Copyright (c) 2021 Elsevier B.V. All rights reserved.