Published June 2016 | Version v1
Journal article

Characterisation of 32P beta source for external radiation protection

  • 1. Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400094 (India)
  • 2. Isotope Production and Applications Division, Bhabha Atomic Research Centre, Mumbai 400094 (India)

Description

Custom-made design of 32P patch sources are used in brachytherapy applications. Use of this source requires external radiation protection. This implies measurement of absorbed dose rate to tissue at a depth of 0.07 mm. Towards this goal, 2.75 mCi 32P patch source was locally developed. Characterization of this source has been carried out by measuring source parameters such as uniformity in the activity distribution and beam uniformity. The characterization also includes output measurements in terms of absorbed dose rate to air using an extrapolation chamber at 11, 20 and 30 cm from the source. Various correction factors which are dependent on the cavity length as well as independent of the cavity length were also determined in this study. The backscatter correction and Bragg–Grapy stopping power ratio were calculated using the Monte Carlo techniques. Using these correction factors and the measured absorbed dose rate to air, absorbed dose rate to tissue at a depth of 0.07 mm was determined. The study also includes measurements of Hp(0.07) and Hp(10) at different source-to-detector distances using an electronic pocket dosimeter. - Highlights: • 32P patch source for external radiation protection. • Characterization of source parameters such as activity and beam uniformity. • Measurement of absorbed dose to tissue using extrapolation chamber. • Determination backscatter factor and stopping power ratio using Monte Carlo technique. • Measurement of Hp(10) and Hp(0.07) using electronic pocket dosimeter.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radmeas.2016.02.034

Additional details

Identifiers

DOI
10.1016/j.radmeas.2016.02.034;
PII
S1350-4487(16)30069-5;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
89
Journal Page Range
p. 52-62
ISSN
1350-4487
CODEN
RMEAEP

Optional Information

Copyright
Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.