Design of the glass pulse-tube cryocooler
Creators
- 1. Department of Mechanical Engineering, University of Wisconsin-Madison 1500 Engineering Dr. Madison, WI 53706 (United States)
Description
With the purpose of generating the curiosity of the public, a pulse-tube cryocooler with regenerator, pulse-tube, inertance tube and reservoir made of glass has been designed constructed and operated. The dimensions of the glass regenerator have been determined using REGEN3.3 [1] from given parameters of the conductive porous medium inside of the regenerator and a 150K target cooling temperature at the cold head. The geometry of the glass pulse-tube and glass inertance tube has been fixed using an approximate design method [2], and the entire system parameters checked using SAGE [3]. The thickness of each glass component is based on a charge pressure of around 7 bar and a pressure ratio of about 1.35. The dimensions of the after-cooler are calculated using ISOHX [4] assuming a gas temperature of 300 K at the inlet of the regenerator. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1757-899X/278/1/012150Additional details
Identifiers
Publishing Information
- Journal Title
- IOP Conference Series. Materials Science and Engineering (Online)
- Journal Volume
- 278
- Journal Issue
- 1
- Journal Page Range
- [6 p.]
- ISSN
- 1757-899X
Conference
- Title
- International Cryogenic Materials Conference
- Acronym
- ICMC-2017
- Dates
- 9-13 Jul 2017
- Place
- Madison, WI (United States)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52070058
- Subject category
- S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COOLING; CRYOGENICS; DESIGN; GEOMETRY; GLASS; HEAT EXCHANGERS; POROUS MATERIALS; PULSES; REGENERATORS
- Descriptors DEC
- MATERIALS; MATHEMATICS