Published February 1, 2016 | Version v1
Journal article

Numerical Evaluation of Effect of Motion of Samples on Ptychographic Imaging and Solution with a Random Phase Modulator

  • 1. School of Physics and Optoelectronic Engineering, Xidian University, Xi'an 710071 (China)

Description

The retrieval of ptychographical imaging encounters a degradation produced by motion of samples. The mechanism of capturing the diffractive patterns of a sample which is motile is simulated numerically. The relation between the retrieval degradation and the amplitude of motion is evaluated quantitatively. Experiments indicate that the reliability and resolution of the complex amplitude retrieval of a sample is inversely proportional to its vibratory amplitude. A random phase modulated aperture is employed to cure the degradation produced by the motion of samples to a certain extent. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/0256-307X/33/2/024204

Additional details

Publishing Information

Journal Title
Chinese Physics Letters
Journal Volume
33
Journal Issue
2
Journal Page Range
[4 p.]
ISSN
0256-307X
CODEN
CPLEEU

INIS

Country of Publication
China
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
48022446
Subject category
S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
Descriptors DEI
AMPLITUDES; APERTURES; CAPTURE; EVALUATION; RANDOMNESS; RELIABILITY; RESOLUTION; SIMULATION
Descriptors DEC
OPENINGS