Published February 1, 2016
| Version v1
Journal article
Numerical Evaluation of Effect of Motion of Samples on Ptychographic Imaging and Solution with a Random Phase Modulator
- 1. School of Physics and Optoelectronic Engineering, Xidian University, Xi'an 710071 (China)
Description
The retrieval of ptychographical imaging encounters a degradation produced by motion of samples. The mechanism of capturing the diffractive patterns of a sample which is motile is simulated numerically. The relation between the retrieval degradation and the amplitude of motion is evaluated quantitatively. Experiments indicate that the reliability and resolution of the complex amplitude retrieval of a sample is inversely proportional to its vibratory amplitude. A random phase modulated aperture is employed to cure the degradation produced by the motion of samples to a certain extent. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0256-307X/33/2/024204Additional details
Identifiers
Publishing Information
- Journal Title
- Chinese Physics Letters
- Journal Volume
- 33
- Journal Issue
- 2
- Journal Page Range
- [4 p.]
- ISSN
- 0256-307X
- CODEN
- CPLEEU
INIS
- Country of Publication
- China
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48022446
- Subject category
- S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Descriptors DEI
- AMPLITUDES; APERTURES; CAPTURE; EVALUATION; RANDOMNESS; RELIABILITY; RESOLUTION; SIMULATION
- Descriptors DEC
- OPENINGS